Sale!

ATS48C59Y

$ 7,515.00

Soft starter for asynchronous motor – ATS48 – 477 A – 208..690 V – 132..560 KW

In stock

Category: Tag:

Description

Soft starter for asynchronous motor – ATS48 – 477 A – 208..690 V – 132..560 KW

Main
range of product
Altistart 48
product or component type
Soft starter
product destination
Asynchronous motors
product specific application
Heavy duty industry and pumps
device short name
ATS48
power supply voltage
208…690 V – 15…10 %
motor power kW
132 kW at 230 V for severe applications
160 kW at 230 V for standard applications
250 kW at 400 V for severe applications
250 kW at 440 V for severe applications
315 kW at 400 V for standard applications
315 kW at 500 V for severe applications
315 kW at 525 V for severe applications
355 kW at 440 V for standard applications
400 kW at 500 V for standard applications
400 kW at 525 V for standard applications
400 kW at 660 V for severe applications
500 kW at 690 V for severe applications
560 kW at 660 V for standard applications
560 kW at 690 V for standard applications
motor power hp
150 hp at 208 V for severe applications
200 hp at 230 V for standard applications
350 hp at 460 V for severe applications
400 hp at 460 V for standard applications
400 hp at 575 V for severe applications
500 hp at 575 V for standard applications
power dissipation in W
1386 W for standard applications
1731 W for standard applications
utilisation category
AC-53A
type of start
Start with torque control (current limited to 5 In)
Icl nominal current
590 A for connection in the motor supply line for standard applications
590 A for connection in the motor supply line for severe applications
Complementary
assembly style
With heat sink
function available
External bypass (optional)
power supply frequency
50…60 Hz – 5…5 %
power supply frequency limits
47.5…63 Hz
device connection
In the motor supply line
discrete output number
2
discrete output type
(LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
output absolute accuracy precision
+/- 5 %
minimum switching current
10 mA at 6 V DC for relay outputs
maximum switching current
Logic output 0.2 A at 30 V DC
Relay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 ms
Relay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms
discrete input number
5
discrete input type
PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
discrete input voltage
24 V <= 30 V
discrete input logic
Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA
starting current
0.4…1.3 Icl adjustable
analogue output type
Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm
communication port protocol
Modbus
connector type
1 RJ45
communication data link
Serial
physical interface
RS485 multidrop
transmission rate
4800, 9600 or 19200 bps
max nodes number
31
protection type
Phase failure: line
Thermal protection: motor
Thermal protection: starter
marking
CE
operating position
Vertical +/- 10 degree
height
670 mm
width
400 mm
depth
300 mm
net weight
51.4 kg
Motor power range AC-3
110…220 kW at 200…240 V 3 phases
250…500 kW at 380…440 V 3 phases
250…500 kW at 480…500 V 3 phases
motor starter type
Soft starter
Environment
electromagnetic compatibility
Conducted and radiated emissions level A conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
standards
EN/IEC 60947-4-2
product certifications
NOM 117
CSA
GOST
DNV
CCC
C-Tick
TCF
UL
SEPRO
noise level
55 dB
relative humidity
0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
ambient air temperature for operation
40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating)
ambient air temperature for storage
-25…70 °C
operating altitude
<= 1000 m without derating
> 1000…2000 m with current derating of 2.2 % per additional 100 m