Description
Soft starter for asynchronous motor – ATS48 – 477 A – 208..690 V – 132..560 KW
range of product |
Altistart 48
|
|
---|---|---|
product or component type |
Soft starter
|
|
product destination |
Asynchronous motors
|
|
product specific application |
Heavy duty industry and pumps
|
|
device short name |
ATS48
|
|
power supply voltage |
208…690 V – 15…10 %
|
|
motor power kW |
132 kW at 230 V for severe applications
160 kW at 230 V for standard applications 250 kW at 400 V for severe applications 250 kW at 440 V for severe applications 315 kW at 400 V for standard applications 315 kW at 500 V for severe applications 315 kW at 525 V for severe applications 355 kW at 440 V for standard applications 400 kW at 500 V for standard applications 400 kW at 525 V for standard applications 400 kW at 660 V for severe applications 500 kW at 690 V for severe applications 560 kW at 660 V for standard applications 560 kW at 690 V for standard applications |
|
motor power hp |
150 hp at 208 V for severe applications
200 hp at 230 V for standard applications 350 hp at 460 V for severe applications 400 hp at 460 V for standard applications 400 hp at 575 V for severe applications 500 hp at 575 V for standard applications |
|
power dissipation in W |
1386 W for standard applications
1731 W for standard applications |
|
utilisation category |
AC-53A
|
|
type of start |
Start with torque control (current limited to 5 In)
|
|
Icl nominal current |
590 A for connection in the motor supply line for standard applications
590 A for connection in the motor supply line for severe applications |
assembly style |
With heat sink
|
|
---|---|---|
function available |
External bypass (optional)
|
|
power supply frequency |
50…60 Hz – 5…5 %
|
|
power supply frequency limits |
47.5…63 Hz
|
|
device connection |
In the motor supply line
|
|
discrete output number |
2
|
|
discrete output type |
(LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
|
output absolute accuracy precision |
+/- 5 %
|
|
minimum switching current |
10 mA at 6 V DC for relay outputs
|
|
maximum switching current |
Logic output 0.2 A at 30 V DC
Relay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 ms Relay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms |
|
discrete input number |
5
|
|
discrete input type |
PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm |
|
discrete input voltage |
24 V <= 30 V
|
|
discrete input logic |
Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA
|
|
starting current |
0.4…1.3 Icl adjustable
|
|
analogue output type |
Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm
|
|
communication port protocol |
Modbus
|
|
connector type |
1 RJ45
|
|
communication data link |
Serial
|
|
physical interface |
RS485 multidrop
|
|
transmission rate |
4800, 9600 or 19200 bps
|
|
max nodes number |
31
|
|
protection type |
Phase failure: line
Thermal protection: motor Thermal protection: starter |
|
marking |
CE
|
|
operating position |
Vertical +/- 10 degree
|
|
height |
670 mm
|
|
width |
400 mm
|
|
depth |
300 mm
|
|
net weight |
51.4 kg
|
|
Motor power range AC-3 |
110…220 kW at 200…240 V 3 phases
250…500 kW at 380…440 V 3 phases 250…500 kW at 480…500 V 3 phases |
|
motor starter type |
Soft starter
|
electromagnetic compatibility |
Conducted and radiated emissions level A conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
|
---|---|---|
standards |
EN/IEC 60947-4-2
|
|
product certifications |
NOM 117
CSA GOST DNV CCC C-Tick TCF UL SEPRO |
|
noise level |
55 dB
|
|
relative humidity |
0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
|
|
ambient air temperature for operation |
40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating) |
|
ambient air temperature for storage |
-25…70 °C
|
|
operating altitude |
<= 1000 m without derating
> 1000…2000 m with current derating of 2.2 % per additional 100 m |