Extendable PLC base Twido – 100..240 V AC supply – 6 I 24 V DC – 4 O relay

In stock

Category: Tag:

Description

Extendable PLC base Twido – 100..240 V AC supply – 6 I 24 V DC – 4 O relay

Main
range of product
Twido
product or component type
Compact base controller
discrete I/O number
10
discrete input number
6
discrete input voltage
24 V
discrete input voltage type
DC
discrete output number
4 relay
[Us] rated supply voltage
100…240 V AC
use of slot
Memory cartridge or realtime clock cartridge
data backed up
Internal RAM lithium, 30 days 10 h 10 year(s)
integrated connection type
Power supply
Non isolated serial link mini DIN, Modbus/character mode master/slave RTU/ASCII RS485) half duplex, 38.4 kbit/s
Complementary
discrete input logic
Sink or source
input voltage limits
20.4…28.8 V
discrete input current
11 mA I0.0 to I0.1
7 mA I0.2 to I0.5
input impedance
2100 Ohm I0.0 to I0.1
3400 Ohm I0.2 to I0.5
filter time
35 µs + programmed filter time for I0.0 to I0.5 at state 1
45 µs + programmed filter time for I0.0 to I0.5 at state 0
insulation between channel and internal logic
1500 Vrms for 1 minute
insulation resistance between channel
None
minimum load
0.1 mA
contact resistance
30000 µOhm
load current
2 A 240 V AC inductive 30 cyc/mn relay output
2 A 240 V AC resistive 30 cyc/mn relay output
2 A 30 V DC inductive 30 cyc/mn relay output
2 A 30 V DC resistive 30 cyc/mn relay output
mechanical durability
20000000 cycles relay output
electrical durability
100000 cycles relay output
current consumption
24 mA 5 V DC at state 1
26 mA 24 V DC at state 1
5 mA 5 V DC at state 0
I/O connection
Non-removable screw terminal block
network frequency
50/60 Hz
supply voltage limits
85…264 V
network frequency limits
47…63 Hz
power supply output current
0.25 A 24 V DC sensors
input current
250 mA
inrush current
35 A
protection type
Power protection internal fuse
power consumption in VA
20 VA 100 V
30 VA 264 V
insulation resistance
> 10 MOhm at 500 V, between I/O and earth terminals
> 10 MOhm at 500 V, between supply and earth terminals
program memory
700 instructions
exact time for 1 Kinstruction
1 ms
system overhead
0.5 ms
memory description
Internal RAM, 128 counters, no floating, no trigonometrical
Internal RAM, 128 internal bits, no floating, no trigonometrical
Internal RAM, 3000 internal words, no floating, no trigonometrical
Internal RAM, 64 timers, no floating, no trigonometrical
free slots
1
realtime clock
Without
counting input number
1 20000 Hz 32 bits
3 5000 Hz 16 bits
analogue adjustment points
1 point adjustable from 0…1023
status LED
PWR 1 LED Green)
1 LED (green)RUN
I/O status 1 LED per channel Green)
Module error (ERR) 1 LED Red)
User pilot light (STAT) 1 LED
depth
2.76 in (70 mm)
height
3.15 in (80 mm)
width
3.54 in (90 mm)
terminals description PLC n°1
ALT
COM_NEG#0-5
(2)IN_DIS#2
(+)PW_OUT_POS
(-)PW_OUT_NEG
(5)IN_DIS#5
(3)IN_DIS#3
(0)IN_DIS#0
(4)IN_DIS#4
TB_TOP
(1)IN_DIS#1
terminals description PLC n°2
COM_POS#0-5
(0)IN_DIS#0
(-)PW_OUT_NEG
(3)IN_DIS#3
(1)IN_DIS#1
(4)IN_DIS#4
ALT_1
TB_TOP
(5)IN_DIS#5
(+)PW_OUT_POS
(2)IN_DIS#2
terminals description PLC n°3
(GND)GROUND
(0)OUT_DIS#0
(2)OUT_DIS#2
(3)OUT_DIS#3
(L)PW
TB_BOTTOM
(N)PW
(1)OUT_DIS#1
(COM1)COM#3
(COM0)COM#0-2
Net Weight
0.51 lb(US) (0.23 kg)
Environment
immunity to microbreaks
10 ms
dielectric strength
1500 V for 1 minute, between I/O and earth terminals
1500 V for 1 minute, between supply and earth terminals
product certifications
UL
CSA
marking
CE
ambient air temperature for operation
32…131 °F (0…55 °C)
ambient air temperature for storage
-13…158 °F (-25…70 °C)
relative humidity
30…95 % without condensation
IP degree of protection
IP20
operating altitude
0…6561.68 ft (0…2000 m)
storage altitude
0.00…9842.52 ft (0…3000 m)
vibration resistance
0.075 mm 10…57 Hz 35 mm symmetrical DIN rail
1 gn 57…150 Hz 35 mm symmetrical DIN rail
1.6 mm 2…25 Hz plate or panel with fixing kit
4 gn 25…100 Hz plate or panel with fixing kit
shock resistance
15 gn 11 ms