Description
| range of product | Modicon X80 |
|---|---|
| product or component type | Power supply module |
| backplane compatibility | Not compatible with BMEXBP..02 |
| product specific application | For severe environments |
| primary voltage | 100…240 V |
| supply circuit type | AC |
| secondary power | 15 W 3.3 V DC at 0…60 °C I/O module logic power supply 31.2 W 24 V DC at 0…60 °C I/O module power supply and processor 11.3 W 3.3 V DC at -25…70 °C I/O module logic power supply 23.4 W 24 V DC at -25…70 °C I/O module power supply and processor 21.6 W 24 V DC at 0…60 °C sensor power supply 16.2 W 24 V DC at -25…70 °C sensor power supply |
| primary voltage limit | 85…264 V |
|---|---|
| network frequency | 50/60 Hz |
| network frequency limits | 47…63 Hz |
| apparent power | 0.07 kVA |
| input current | 0.52 A 240 V 1.04 A 115 V |
| inrush current | 30 A 120 V 60 A 240 V |
| I²t on activation | 1 A².s 120 V 3 A².s 240 V |
| It on activation | 0.05 A.s 120 V 0.07 A.s 240 V |
| protection type | Internal fuse not accessible for primary circuit Overload protection for secondary circuit Overvoltage protection for secondary circuit Short-circuit protection for secondary circuit |
| current at secondary voltage | 0.9 A 24 V DC sensor power supply 1.3 A 24 V DC I/O module power supply and processor 4.5 A 3.3 V DC I/O module logic power supply |
| maximum power dissipation in W | 8.5 W |
| status LED | 1 LED (green) rack voltage OK 1 LED (green) sensor voltage |
| control type | RESET push-button cold restart |
| electrical connection | 1 connector 2 pin(s)alarm relay 1 connector 5 pin(s)line supply, protective earth, 24 V DC input sensor |
| insulation resistance | >= 100 MOhm primary/ground >= 100 MOhm primary/secondary |
| net weight | 0.36 kg |
| immunity to microbreaks | 1 ms |
|---|---|
| dielectric strength | 1500 V primary/secondary I/O module logic power supply 1500 V primary/secondary I/O module power supply and processor 2300 V primary/secondary sensor power supply 1500 V primary/ground 500 V 24 V sensor output/ground |
| vibration resistance | 3 gn |
| shock resistance | 30 gn |
| IP degree of protection | IP20 |
| directives | 2014/35/EU – low voltage directive 2014/30/EU – electromagnetic compatibility |
| product certifications | CE UL CSA RCM EAC Merchant Navy |
| standards | EN 61131-2 EN/IEC 61010-2-201 UL 61010-2-201 CSA C22.2 No 61010-2-201 IACS E10 EN/IEC 61000-6-5, interface type 1 and type 2 EN/IEC 61850-3, location G |
| environmental characteristic | Gas resistant class Gx conforming to ISA S71.04 Gas resistant class 3C4 conforming to IEC 60721-3-3 Dust resistant class 3S4 conforming to IEC 60721-3-3 Sand resistant class 3S4 conforming to IEC 60721-3-3 Salt resistant level 2 conforming to IEC 68252 Mold growth resistant class 3B2 conforming to IEC 60721-3-3 Fungal spore resistant class 3B2 conforming to IEC 60721-3-3 Hazardous location class I division 2 |
| ambient air temperature for storage | -40…85 °C |
| ambient air temperature for operation | -25…70 °C |
| relative humidity | 5…95 % at 55 °C without condensation |
| protective treatment | Conformal coating |
| operating altitude | 0…2000 m 2000…5000 m with derating factor |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 13.27 cm |
| Package 1 Width | 15.449 cm |
| Package 1 Length | 15.68 cm |
| Package 1 Weight | 500.0 g |
| Unit Type of Package 2 | S04 |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 40.0 cm |
| Package 2 Length | 60.0 cm |