Sale!

XPSBC3110

Original price was: $ 975.00.Current price is: $ 710.00.

Module XPSBC – two-hand control – 24 V AC XPSBC3110

In stock

Category: Tag:

Description

Module XPSBC – two-hand control – 24 V AC XPSBC3110

Main
range of product
Preventa Safety automation
product or component type
Preventa safety module
safety module name XPSBC3110
safety module application
For electrical monitoring of two-hand control stations
function of module
Monitoring two-hand control station
safety level
Can reach PL e/category 4 conforming to EN/ISO 13849-1
safety reliability data
MTTFd = 63.9 years conforming to EN/ISO 13849-1
DC > 99 % conforming to EN/ISO 13849-1
PFHd = 1.75E-8 1/h conforming to EN/IEC 62061
connections – terminals
Captive screw clamp terminals, 1 x 0.14…1 x 2.5 mm² flexible without cable end
Captive screw clamp terminals, 1 x 0.14…1 x 2.5 mm² solid without cable end
Captive screw clamp terminals, 1 x 0.25…1 x 1.5 mm² flexible with cable end, with bezel
Captive screw clamp terminals, 1 x 0.25…1 x 2.5 mm² flexible with cable end, without bezel
Captive screw clamp terminals, 2 x 0.14…2 x 0.75 mm² flexible without cable end
Captive screw clamp terminals, 2 x 0.14…2 x 0.75 mm² solid without cable end
Captive screw clamp terminals, 2 x 0.25…2 x 1 mm² flexible with cable end, without bezel
Captive screw clamp terminals, 2 x 0.5…2 x 1.5 mm² flexible with cable end, with double bezel
output type
Relay, 2 NO circuit(s), volt-free
number of additional circuits
1 NC
[Us] rated supply voltage
24 V AC – 15…10 %
Complementary
synchronisation time between inputs
0.5 s
supply frequency
50/60 Hz
power consumption in VA
6 VA
input protection type
Internal, electronic
number of inputs
1 NC + NO
input voltage
30 V
input current
50 mA
input compatibility
Two-hand control conforming to EN 574/ISO 13851-III C
[Uc] control circuit voltage
48 V DC
breaking capacity
180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
breaking capacity
1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
[Ith] conventional free air thermal current
2.5 A
associated fuse rating
4 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
minimum output current
10 mA for relay output
minimum output voltage
17 V for relay output
maximum response time on input open
30 ms
[Ui] rated insulation voltage
300 V (pollution degree 2) conforming to IEC 60947-5-1
300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage
4 kV overvoltage category III conforming to IEC 60947-5-1
4 kV overvoltage category III conforming to DIN VDE 0110 part 1
local signalling
3 LEDs
mounting support
35 mm symmetrical DIN rail
net weight
0.4 kg
Environment
standards
EN/IEC 60204-1
EN 574 type III C/ISO 13851
EN/IEC 60947-5-1
product certifications
CSA
UL
TÜV
IP degree of protection
IP20 (terminals) conforming to EN/IEC 60529
IP40 (enclosure) conforming to EN/IEC 60529
ambient air temperature for operation
-10…55 °C
ambient air temperature for storage
-25…85 °C
Packing Units
Package 1 Weight
0.439 kg
Package 1 Height
0.650 dm
Package 1 width
1.350 dm
Package 1 Length
0.870 dm