Description
Module XPSBC – two-hand control – 24 V AC XPSBC3110
| range of product |
Preventa Safety automation
|
|
|---|---|---|
| product or component type |
Preventa safety module
|
|
| safety module name | XPSBC3110 | |
| safety module application |
For electrical monitoring of two-hand control stations
|
|
| function of module |
Monitoring two-hand control station
|
|
| safety level |
Can reach PL e/category 4 conforming to EN/ISO 13849-1
|
|
| safety reliability data |
MTTFd = 63.9 years conforming to EN/ISO 13849-1
DC > 99 % conforming to EN/ISO 13849-1 PFHd = 1.75E-8 1/h conforming to EN/IEC 62061 |
|
| connections – terminals |
Captive screw clamp terminals, 1 x 0.14…1 x 2.5 mm² flexible without cable end
Captive screw clamp terminals, 1 x 0.14…1 x 2.5 mm² solid without cable end Captive screw clamp terminals, 1 x 0.25…1 x 1.5 mm² flexible with cable end, with bezel Captive screw clamp terminals, 1 x 0.25…1 x 2.5 mm² flexible with cable end, without bezel Captive screw clamp terminals, 2 x 0.14…2 x 0.75 mm² flexible without cable end Captive screw clamp terminals, 2 x 0.14…2 x 0.75 mm² solid without cable end Captive screw clamp terminals, 2 x 0.25…2 x 1 mm² flexible with cable end, without bezel Captive screw clamp terminals, 2 x 0.5…2 x 1.5 mm² flexible with cable end, with double bezel |
|
| output type |
Relay, 2 NO circuit(s), volt-free
|
|
| number of additional circuits |
1 NC
|
|
| [Us] rated supply voltage |
24 V AC – 15…10 %
|
| synchronisation time between inputs |
0.5 s
|
|
|---|---|---|
| supply frequency |
50/60 Hz
|
|
| power consumption in VA |
6 VA
|
|
| input protection type |
Internal, electronic
|
|
| number of inputs |
1 NC + NO
|
|
| input voltage |
30 V
|
|
| input current |
50 mA
|
|
| input compatibility |
Two-hand control conforming to EN 574/ISO 13851-III C
|
|
| [Uc] control circuit voltage |
48 V DC
|
|
| breaking capacity |
180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output |
|
| breaking capacity |
1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
|
|
| [Ith] conventional free air thermal current |
2.5 A
|
|
| associated fuse rating |
4 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
|
|
| minimum output current |
10 mA for relay output
|
|
| minimum output voltage |
17 V for relay output
|
|
| maximum response time on input open |
30 ms
|
|
| [Ui] rated insulation voltage |
300 V (pollution degree 2) conforming to IEC 60947-5-1
300 V (pollution degree 2) conforming to DIN VDE 0110 part 1 |
|
| [Uimp] rated impulse withstand voltage |
4 kV overvoltage category III conforming to IEC 60947-5-1
4 kV overvoltage category III conforming to DIN VDE 0110 part 1 |
|
| local signalling |
3 LEDs
|
|
| mounting support |
35 mm symmetrical DIN rail
|
|
| net weight |
0.4 kg
|
| standards |
EN/IEC 60204-1
EN 574 type III C/ISO 13851 EN/IEC 60947-5-1 |
|
|---|---|---|
| product certifications |
CSA
UL TÜV |
|
| IP degree of protection |
IP20 (terminals) conforming to EN/IEC 60529
IP40 (enclosure) conforming to EN/IEC 60529 |
|
| ambient air temperature for operation |
-10…55 °C
|
|
| ambient air temperature for storage |
-25…85 °C
|
| Package 1 Weight |
0.439 kg
|
|
|---|---|---|
| Package 1 Height |
0.650 dm
|
|
| Package 1 width |
1.350 dm
|
|
| Package 1 Length |
0.870 dm
|