Sale!

SEPAM 59658

Original price was: $ 617.00.Current price is: $ 575.00.

In stock

Category:

Description

Main
Range of product Sepam series 40
Sepam series 80 NPP
Sepam series 60
Sepam series 80
Device short name ACE850TP
Complementary
communication port protocol ARP network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX
FTP network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX
HTTP network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX
IEC 61850 network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX
Modbus RTU network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX
Modbus TCP/IP network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX
RSTP 801.1d 2004 network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX
SNMP network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX
SNTP network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX
local signalling Green LED1 for energized (front face)
Green LED2 for communication status ok (front face)
Green LED3 off for port 2 Ethernet 10 Mbit/s (front face)
Green LED3 on for port 2 Ethernet 100 Mbit/s (front face)
Green LED4 flashing for port 2 Ethernet sending data and receiving data (front face)
Green LED5 off for port 1 Ethernet 10 Mbit/s (front face)
Green LED5 on for port 1 Ethernet 100 Mbit/s (front face)
Green LED6 flashing for port 1 Ethernet sending data and receiving data (front face)
Red LED1 flashing for not set up or not base-unit connected (front face)
Red LED1 off for de-energized (front face)
Red LED1 remains ON for fault (front face)
[Us] rated supply voltage 110…240 V AC tolerance: – 20…10 %
24…250 V DC tolerance: – 20…10 %
Mounting mode Fixed
Mounting support Symmetrical DIN rail
Height 127 mm
Width 171 mm
Depth 58 mm
Product weight 0.4 kg
mechanical robustness Earthquakes in operation (level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3
Earthquakes in operation (level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3
Jolts de-energized (level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2
Shocks de-energized (level: 2) : 30 Gn/11 ms conforming to IEC 60255-21-2
Shocks in operation (level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2
Vibrations de-energized (level: 2) : 2 Gn, 10 Hz…150 Hz conforming to IEC 60255-21-1
Vibrations in operation (level: 2) : 1 Gn, 10 Hz…150 Hz conforming to IEC 60255-21-1
Vibrations in operation (level: Fc) : 2 Hz…13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6
maximum cable distance between devices <100 m
auxiliary connection terminal Functional earth: ring lug 1 pin(s) 1 cable(s) tinned copper braid 4 mm²
Protective earth: screw-type connector 1 pin(s) 1 cable(s) wire 2.5 mm² <3 m
Supply: screw-type connector 3 pin(s) 1 cable(s) wire 0.5…2.5 mm²
Supply: screw-type connector 3 pin(s) 1 cable(s) wire 1.5 mm²
Supply: screw-type connector 3 pin(s) 1 cable(s) wire 2.5 mm²
Supply: screw-type connector 3 pin(s) 2 cable(s) wire 0.5…1 mm²
Supply: screw-type connector 3 pin(s) 2 cable(s) wire 1 mm²
Supply: screw-type connector 4 pin(s) 1 cable(s) wire 0.5…2.5 mm²
Supply: screw-type connector 4 pin(s) 1 cable(s) wire 1.5 mm²
Supply: screw-type connector 4 pin(s) 1 cable(s) wire 2.5 mm²
Supply: screw-type connector 4 pin(s) 2 cable(s) wire 0.5…1 mm²
Supply: screw-type connector 4 pin(s) 2 cable(s) wire 1 mm²
wire stripping length Supply: 8 mm
Environment
electromagnetic compatibility 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV MC and MD, conforming to ANSI C37.90.1
1 MHz damped oscillating wave: (immunity tests-conducted disturbances), III, 2.5 kV MC, 1 kV MD, conforming to IEC 60255-22-1
100 kHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV MC, 1 kV MD, conforming to IEC 61000-4-12
Conducted disturbance emission: (emission tests), conforming to IEC 60255-25
Conducted disturbance emission: (emission tests), B, conforming to EN 55022
Disturbing field emission: (emission tests), conforming to IEC 60255-25
Disturbing field emission: (emission tests), A, conforming to EN 55022
Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 4 kV contact, conforming to ANSI C37.90.3
Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2
Fast transient bursts: (immunity tests-conducted disturbances), 4kV, 2.5 kHz, conforming to ANSI C37.90.1
Fast transient bursts: (immunity tests-conducted disturbances), A or B, 4kV, 2.5 kHz/2 kV, 5 kHz, conforming to IEC 60255-22-4
Fast transient bursts: (immunity tests-conducted disturbances), IV, 4kV, 2.5 kHz, conforming to IEC 61000-4-4
Immunity to conducted RF disturbances: (immunity tests-conducted disturbances), 10 V, conforming to IEC 60255-22-6
Immunity to magnetic fields at network frequency: (immunity tests-radiated disturbances), IV, 30 A/m (continuous)-300 A/m (13 s), conforming to IEC 61000-4-8
Immunity to radiated fields: (immunity tests-radiated disturbances), 10 V/m, 80 MHz…1 GHz, conforming to IEC 60255-22-3
Immunity to radiated fields: (immunity tests-radiated disturbances), 35 V/m, 25 MHz…1 GHz, conforming to ANSI C37.90.2 (1995)
Immunity to radiated fields: (immunity tests-radiated disturbances), III, 10 V/m, 80 MHz…2 GHz, conforming to IEC 61000-4-3
Surges: (immunity tests-conducted disturbances), III, 2 kV MC, 1 kV MD, conforming to IEC 61000-4-5
Voltage interruptions: (immunity tests-conducted disturbances), 100 %, 10 ms, conforming to IEC 60255-11
climatic withstand Influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.02 ppm NO2, 0.01 ppm Cl2 conforming to IEC 60068-2-60
Continuous exposure to damp heat (in operation) : Ca: 10 days, 93 % RH, 40 °C (104 °F) conforming to IEC 60068-2-3
Continuous exposure to damp heat (in storage) : Ca: 56 days, 93 % RH, 40 °C (104 °F) conforming to IEC 60068-2-3
Exposure to cold (in operation) : Ab: – 25 °C (- 13 °F) conforming to IEC 60068-2-1
Exposure to cold (in storage) : Ab: – 25 °C (- 13 °F) conforming to IEC 60068-2-1
Exposure to dry heat (in operation) : Bb: 70 °C (158 °F) conforming to IEC 60068-2-2
Exposure to dry heat (in storage) : Bb: 70 °C (158 °F) conforming to IEC 60068-2-2
Influence of corrosion/gaz test 2 (in operation) : C: 21 days, 75 % RH, 25 °C (- 13 °F), 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60
Salt mist (in operation) : Kb/2 conforming to IEC 60068-2-52
Temperature variation with specified variation rate (in operation) : Nb: – 25 °C to 70 °C (- 13 °F to 158 °F) 5 °C/min (41 °F/min) conforming to IEC 60068-2-14
Ambient air temperature for operation -25…70 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 9.800 cm
Package 1 Width 16.700 cm
Package 1 Length 19.800 cm
Package 1 Weight 721 g
Unit Type of Package 2 S03
Number of Units in Package 2 6
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 4.733 kg
Unit Type of Package 3 P12
Number of Units in Package 3 48
Package 3 Height 44.500 cm
Package 3 Width 80.000 cm
Package 3 Length 120.000 cm
Package 3 Weight 49.784 kg